Plasma Cleaner

Home /Plasma Cleaner /

Lab Vacuum Plasma Cleaner

hot products

LATEST NEWS

Shipping injection molding machine to America

Shipping injection molding machine to America

2021-09-06

Mini desktop injection machine is the most cost-effective way to produce the small plastic components in the market. As a redesigned and optimized mod

Delivery fully stainless steel spray dryer to Thailand successfully

Delivery fully stainless steel spray dryer to Thailand successfully

2021-07-16

Delivery fully stainless steel spray dryer to Thailand successfully The spray dryer is one of our best selling product. We have exported many machines

Delivery dry ice blasting machine to AUE

Delivery dry ice blasting machine to AUE

2021-07-05

Delivery dry ice blasting machine to AUE Dry ice blasting is a revolutionary blasting method that uses  dry ice pellets as the blasting material.

Customer from America orders Fully stainless steel Spray dryer

Customer from America orders Fully stainless steel Spray dryer

2021-06-23

Laboratory spray dryer delivery America successfully Ollital Technology specialize in 2L 5L 10L/hour laboratory spray dryer, we just shipped one full

Lab Vacuum Plasma Cleaner

  • Model Number:

    OLT-PS-8
  • Compliance:

    CE Certified
  • Minimum Order Quantity:

    1
  • Voltage:

    108V-380V 50/60HZ
  • Power:

    1000W
  • Warranty:

    3 year
  • Dimension(L*W*H):

    1805(W)×1988(D)×1842(H) mm
  • Packaging Details:

    Export wooden package
  • Delivery Time:

    8-10 day
  • Product Details

                 Lab Vacuum Plasma Cleaner

plasma cleaner

System standard accessories

Equipment size

1105W * 1488D * 1842Hmm (2158mm with signal light height)

Horizontal plate

8layer

battery lead plate

402W * 450Dmm

Gas flow controller

2-circuit process gases, 0-300ml/min

Vacuum measurement

Japanese ulvac vacuum gauge

Human machine interface touch screen

SD independent research and development

Electrode spacing

48mm

Signal indicator

3 ribbon alert

Vacuum pump

90m3/h bipolar oil pump

System Power & Machinery

Power supply

AC380V, 50/60Hz . Rated power 5000W

System weight (device host / vacuum pump)

<600Kg

Equipment host size

1805(W)×1988(D)×1842(H) mm

RF power supply

RF power frequency

13.56MHz

RF power supply

1000W

RF power matcher

Fully automatic matching, leading air capacitance technology

Equipment necessary conditions

Power supply

AC380V, 50/60Hz, three-phase five-wire , 7.5KVA

Compressed air requirements

Anhydrous oil-free CDA 60~90psig

Air draft system

 2 cubic /   minute, the central exhaust gas treatment pipeline can be

System ambient temperature requirements

≤30℃(best room temperature)

Process gas requirements

15~20psig Purity 99.996% or above


(1) low processing temperature

The processing temperature can be as low as 80℃ and below 50 ℃. Low processing temperatures ensure no thermal effects on the sample surface.

(2) no pollution during the whole process

The plasma cleaner itself is a very environmentally friendly device that does not cause any pollution and does not cause any pollution during the treatment process. 

(3) stable treatment effect

The treatment effect of plasma cleaning is very uniform and stable, and the conventional sample maintains good effect for a long time after treatment.

(4) It can handle samples of various shapes

For complex figurate samples, plasma cleaning can find the right solution.Vacuum plasma cleaning can clean the internal position of the solid sample.

Vacuum plasma cleaner action principle:

1.Etching on the surface of the material - physical effect

A large number of active particles in the plasma, such as a large number of ions, excited molecules, and free radicals, act on the surface of the solid sample, which not only removes the original contaminants and impurities, but also produces an etching effect to roughen the surface of the sample and form many fine pits, which increases the specific surface of the sample,improves the wetting properties of solid surfaces.

2.Activation bond energy, cross-linking

The energy of the particles in the plasma is between 0 and 20 eV, and most of the bond energy in the polymer are between 0 and 10 eV. Therefore, after the plasma acts on the solid surface, the original chemical bond on the solid surface can be broken. Free radicals in the plasma form a network of crosslinked structures with these bonds, greatly activating surface activity. 

3.Formation of new functional groups - chemical action

If a reactive gas is introduced into the electric discharge gas, a complicated chemical reaction occurs on the surface of the activated material, and new functional groups such as hydrocarbonyl, amidogen, carboxyl group, and the like are introduced, and these functional groups are all active groups, which can significantly improve the surface activity of the material.

CE Certificated Laboratoty mini Plasma Cleaner for Si, glass, metal piecesCE Certificated Laboratoty mini Plasma Cleaner for Si, glass, metal piecesCE Certificated Laboratoty mini Plasma Cleaner for Si, glass, metal pieces

Company Information

CE Certificated Laboratoty mini Plasma Cleaner for Si, glass, metal pieces





Send Us An Inquiry
We will contact you as soon as possible!
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

RELATED PRODUCTS

Ollital Technology  would like to establish win-win business cooperation with distributors all over the world.